Install flue pipes through roofs or exterior walls.
Stove flue pipe installation.
Steel vitreous stove pipe non insulated is often used for the first section of pipe on top of the stove.
Drill two holes one on each side of the piece of stove pipe to install the damper flap inside the stove pipe.
Chimneys and flues are also available in a number of different materials stainless steel concrete pumice clay or ceramic and plastic.
1 start your system with a length of single wall vitreous enamel stove pipe in the same diameter as the outlet on the stove.
2 connect a single to twin wall adapter to convert from this single wall pipe to insulated twin wall pipe a minimum of 150mm before reaching any surface ceiling or wall.
You need at least one length of stove pipe to connect directly to your log burner s flue outlet.
When a flue pipe travels farther than 3 m 10 feet to reach the insulated chimney break the amount of pipe into sections.
For the exact rules in your area check with a local wood heat retailer chimney sweep or building inspector.
Measure the distance from the wood burning stove flue collar to the collar on the insulated chimney using a measuring tape.
Lengths of twin wall are 250mm 500mm.
Your furnace or wood stove creates gases when heating your home.
Flue pipe run internally and vertically straight up through the roof externally.
Installation rules for flue pipes also called stove pipe smoke pipe chimney connector etc the rules provided here are based on the csa installation code used in canada.
Installing a flue pipe helps to vent these exhaust gases outside.
It must not be used to go through a wall or ceiling except directly into a brick stone chimney.
Single wall vitreous enamelled stove pipe is needed for every installation of a wood burning stove.
Insert the handle through the damper flap and stove pipe.
Building regulations for stove and flue installations building regulations for stove installations any work that affects an existing chimney including installation of a stove or flue liner or creates a new chimney is considered building work and so comes under the building regulations.
To exit the room whether out through a wall or through a ceiling you must use twin wall flue pipe and then stay with twin wall flue pipe to the cowl.
You may need to replace an old flue that no longer connects properly or install a new pipe while upgrading your heating system.
Cut stove pipe to length.
Connecting flue pipes pipe specifically designed to connect an appliance to the flue or chimney.
You would need two 1 5 m 5 foot sections of flue pipe to travel a 3 m 10 foot distance.